Eine intreXis AG Speisung hält neben den Standard EMV Normen spezielle, applikationsspezifische Normen ein. Speziell in den Bereichen Medizin, Bahn und Militär haben wir grosse Erfahrung.
Die Vielfalt der verschiedenen Normen ist enorm:
EN61000-4-2 Electrostatic discharge: ±8kV air-discharge and ±6kV contact-discharge; EN61000-4-3 Radio-frequency electromagnetic field immunity: 20V/m, 80-1000MHz; EN61000-4-4 Fast transients: ±2kV; EN61000-4-5 Surges: ±2kV line to ground, ±1kV line to line; EN61000-4-6 Radio-frequency common mode immunity: 10Vrms, 0.15-80MHz; EN61000-4-8 Power frequency magnetic field immunity test: 30A/m; EN61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests: 30-100% at 10-50ms ok without battery at nominal load; EN55011 Conducted Emission: class A+B; EN55011 Radiated emission: Class A+B; EN61000-3-2 Limits for harmonics (active PFC); EN61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker ; MIL-STD 461D/462D...
Was man mit unseren Stromversorgungen bauen kann.
Was man über unsere Stromversorgungen wissen muss.
Was man von unseren Stromversorgungen erwarten darf.
Die Leidenschaft für Technologie und Performance ist unser Antrieb, kontinuierlich noch bessere und effizientere Stromversorgungssysteme zu entwickeln. Das Resultat ist das derzeit umfassendste Portfolio von DC/DC Wandlern für Bahnanwendungen.